AQUATEC CHEMICAL INTL INC -- DESCALER G -- 7930-00F050475
===================== Product Identification ===================== Product ID:DESCALER G MSDS Date:03/02/1989 FSC:7930 NIIN:00F050475 === Responsible Party === Company Name:AQUATEC CHEMICAL INTL INC Address:408 AUBURN AVE City:PONTIAC State:MI ZIP:48342-3208 Country:US Info Phone Num:810-334-4747 Emergency Phone Num:810-456-8551 CAGE:0NEA5 === Contractor Identification === Company Name:AQUATEC CHEMICAL INTERNATIONAL INC Address:7844 MADISON AVE SUITE 111 City:FAIR OAKS State:CA ZIP:95628-3502 Country:US Phone:916-863-0501;313-334-4747 CAGE:0NEA5 Company Name:CLOW CORP WATER MANAGEMENT DIV Address:408 AUBURN AVE Box:City:PONTIAC State:MI ZIP:48058-2622 Country:US CAGE:9Y834 ============= Composition/Information on Ingredients ============= Ingred Name:HYDROCHLORIC ACID, HYDROGEN CHLORIDE, MURIATIC ACID HYDROCHLORIDE CAS:7647-01-0 RTECS #:MW4025000 Fraction by Wt: 25% Other REC Limits:7 PPM OSHA PEL:5 PPM ACGIH TLV:C 11 MG/CUM EPA Rpt Qty:5000 LBS DOT Rpt Qty:5000 LBS Ingred Name:FORMALDEHYDE, FORMALIN (SUSPECTED HUMAN CARCINOGEN BY IARC; ACGIH; SUSPECTED CARCINOGEN BY NTP; IARC - GROUP 2A) *96-2* CAS:50-00-0 RTECS #:LP8925000 ACGIH TLV:0.37 MG/CUM IC (2A) EPA Rpt Qty:100 LBS DOT Rpt Qty:100 LBS Ingred Name:N,N-DIETHYLTHIOUREA CAS:105-55-5 RTECS #:YS9800000 Other REC Limits:NTP CARCINOGEN ===================== Hazards Identification ===================== Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO Health Hazards Acute and Chronic:EYES/SKIN: WILL PRODUCE SEVERE/PERMANENT INJURY(TISSUE DESTROYED/CHANGED). INHALATION: SEVERE IRRITATION & POSSIBLE BURNS/TISSUE DAMAGE. INGESTION: CORROSIVE TISSUE DAMAGE. EXPOSURE MAY CAUSE SKIN, MU COUS MEMBRANES/RESPIRATORY TRACT ULCERATION/ALLERGIC REACTIONS. Explanation of Carcinogenicity:SEE INGREDIENTS. Effects of Overexposure:IRRITATION, BURNS. Medical Cond Aggravated by Exposure:ALLERGIC REACTIONS. ======================= First Aid Measures ======================= First Aid:EYES: IMMEDIATELY FLUSH W/LARGE AMOUNTS OF WATER FOR 15 MINS. SKIN: WASH W/WATER FOR 15 MINS. INHALATION: REMOVE TO FRESH AIR. GIVE CPR/OXYGEN IF NEEDED. INGESTION: DON'T INDUCE VOMITING. DRINK LOTS O F WATER. OBTAIN MEDICAL ATTENTION IN ALL CASES. ===================== Fire Fighting Measures ===================== Flash Point:NONE Fire Fighting Procedures:WEAR FULL BODY PROTECTIVE CLOTHING & SCBA. WATER SPRAY MAY BE USED TO KEEP FIRE EXPOSED CONTAINERS COOL. Unusual Fire/Explosion Hazard:NON-COMBUSTIBLE. CONTACT W/ALUMINUM, ZINC & OTHER METALS CAN GENERATE HYDROGEN WHICH IS EXPLOSIVE. ================== Accidental Release Measures ================== Spill Release Procedures:REMOVE SOURCES OF IGNITION. COVER CONTAMINATED SURFACES W/SODA ASH/SODIUM BICARBONATE. MIX & ADD WATER, IF NECESSARY; SCOOP UP SLURRY. CHECK TO SEE IF NEUTRALIZED. FLUSH TO SEWER W/WATER, IF ALLOWED. ====================== Handling and Storage ====================== Handling and Storage Precautions:STORE IN COOL, WELL VENTILATED AREA. KEEP DRUMS TIGHTLY CLOSED WHEN NOT IN USE. KEEP AWAY FROM HEAT & OPEN FLAME. KEEP CONTAINER CLOSED. Other Precautions:USE W/ADEQUATE VENTILATION. DON'T GET IN EYES, SKIN/CLOTHING. AVOID BREATHING VAPOR. ============= Exposure Controls/Personal Protection ============= Respiratory Protection:USE A NIOSH APPROVED RESPIRATOR IF LOCAL EXPOSURE LIMITS MAY BE EXCEEDED. Ventilation:GENERAL ROOM, PLUS LOCAL EXHAUST AT RELEASE POINTS. Protective Gloves:RUBBER Eye Protection:FACE SHIELD/CHEMICAL SPLASH GOGGLES Other Protective Equipment:RUBBER SUIT & RUBBER BOOTS, EMERGENCY EYE WASH FACILITY. Work Hygienic Practices:REMOVE/LAUNDER CONTAMINATED CLOTHING BEFORE REUSE. DISCARD CONTAMINATED SHOES. Supplemental Safety and Health PH OF 1% SOLUTION IS 1.4. ================== Physical/Chemical Properties ================== Boiling Pt:B.P. Text:180F Vapor Pres:27 Vapor Density:>1 Spec Gravity:1.123 pH:(SUPP) Evaporation Rate & Reference:LIGHTER THAN AIR Solubility in Water:MISCIBLE Appearance and Odor:PURPLE LIQUID W/PUNGENT ODOR Percent Volatiles by Volume:0/WT ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES ALKALI Stability Condition to Avoid:HEAT, OPEN FLAME & SOURCES OF IGNITION. Hazardous Decomposition Products:HYDROCHLORIC ACID-TOXIC. METAL CONTACT: LIBERATES HYDROGEN. ==================== Disposal Considerations ==================== Waste Disposal Methods:DILUTE & NEUTRALIZE W/CONTROLLED QUANTITY OF ALKALI. DISPOSE OF THROUGH A WASTE TREATMENT PLANT, IAW/FEDERAL, STATE & LOCAL REGULATIONS. CORROSIVE MATERIAL UN1789. Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.